Frequently Asked Questions
How lightning and thunderstorms are detected? How do you locate lightning? Find the answers to your most frequently asked questions about lightning detection and our services.
A question about...
How do you detect lightning?
A lightning discharge emits electromagnetic signals in a large spectrum of frequencies, from very low frequency ones up to the visible spectrum (the “light” of lightning) and beyond. Part of this spectrum is composed of LF (Low Frequency) waves traveling along the ground over hundreds of kilometers in every direction from the discharge.
Lightning detection sensors are electromagnetic antennas able to detect and characterize the local electromagnetic field changes caused by lightning. These sensors do not work individually, but as a network. It means that the information provided in real time by all the LS7002 sensors is processed by a software called the TLP (Total Lightning Processor) that computes the stroke’s location and its electrical characteristics (peak current amplitude and polarity). Contrary to standalone sensors like weather stations, such a network provides a seamless detection dataset over its region of coverage.
What is the difference between a lightning flash, a return-stroke, a ground strike point and an IC (Intra-Cloud) pulse?
Lightning is made of several types of electrical discharges aiming at neutralizing the electrical charges distributed in the thundercloud and on the ground. These discharges, generated by the strong electrical fields present inside the cloud and between the cloud and the ground, transfer electrical currents ranging from few amperes up to several hundred.
When a discharge occurs between the cloud and the ground, regardless its direction (downward or upward), it is called a return-stroke or a stroke. Several return-strokes may flow in one or several channels, each channel creating a ground strike point. When the discharge remains inside the cloud, it is defined as an Intra-Cloud (IC) pulse.
A lightning flash is the result of the occurrence of all the discharges, strokes or IC pulses. For historical reasons, lightning locating system operators define a Cloud-to-Ground (CG) flash based on the characteristics of the first return-stroke, or of the first IC pulse for an IC flash.
How do you locate lightning accurately?
Vaisala’s LS7002 sensors provide two key parameters used to localize strokes: the incoming direction of the LF (Low Frequency) electromagnetic signal in respect to the geographical North and its time of arrival at the sensor. This allows networks composed of such sensors, which is the case of the METEORAGE network – the European Lightning Detection Network (ELDN),, to use the Vaisala’s IMPACT method (IMProved Accuracy from Combined Technology) which combines both angle and time to accurately locate stroke positions. Combining angle and time measurements guarantees a high resolution and optimum lightning data quality with a minimum number of sensors.
Sensors from other manufacturers only provides the time of arrival because this requires simpler hardware, with one electromagnetic antenna instead of two, thus making the sensors less expensive. The consequence is that with a similar number of sensors, their network will provide a significantly lower data quality.
How do you differentiate the IC (Intra-Cloud) and the CG (Cloud-to-Ground) lightning activity?
Two different methods are typically used by lightning detection networks to do this IC/CG discrimination:
- Waveform recognition. This is what is used by the METEORAGE network and other networks of Vaisala technology. Signals generated by CG and IC discharges are different enough to allow an efficient classification of the discharges by the TLP collecting measurements from a “normal” commercial network, meaning a baseline between sensors in the hundreds of km.
- Altitude measurement. Technically, the angles of arrival can be used to determine the altitude, and thus differentiate ICs from CGs. However, the measurement uncertainty from hundreds of km away is far too important to be a reliable IC/CG discrimination parameter. Claims that this can be done properly are misleadingly based on the case study of an extremely dense network covering a single city, where dozens of sensors were installed with a baseline of a few tens of km. Obviously, an entire country cannot be covered like this as it would require thousands of sensors.
As with every measurement, while the discrimination process between IC and CG is optimized, it isn’t perfect. So, it might still happen sometimes that a CG stroke is mistakenly characterized as an IC stroke, and vice versa.
When there is a strong suspicion of lightning-related incident but no matching CG stroke, we recommend having a look at the IC activity as a secondary safety step, to see if there isn’t an IC matching the precise time and location of the incident and which might be a mis-characterized CG.
A reliable IC/CG discrimination is also crucial to adequately compute lightning density values (Nsg/Ng), as explained in the IEC 62858 international standard.
Why is that important to detect all the lightning activity, including the ICs (Intra-Clouds)?
By definition, Intra-Cloud pulses do not hit the ground and cannot cause damages. However, detecting them is useful for three main applications:
- For real-time services, such as lightning alarms and the tracking of thunderstorms, intra-cloud activity is crucial as most of the electrical activity in a thunderstorm remains in the atmosphere (about 70 to 90% of the discharges are IC pulses). A storm usually starts with intra-cloud pulses before anything hits the ground. So, a thunderstorm can be spotted sooner, and an alarm can be triggered using such events, giving our customers more time to react.
- Thunderstorm cells sometimes exhibit a sudden increase of the frequency of lightning flashes, called the Lightning Jump, which is mainly driven by IC flashes. This lightning jump is used to anticipate severe phenomena in a thunderstorm like strong winds, hail and heavy precipitations.
- Upward lightning flashes are a specific type of lightning which isn’t common but can be triggered by very tall structures such as wind turbines. They are typically composed of both CG strokes and IC pulses.
What equipment / software must be installed to gain access to your lightning services?
Contrary to standalone detection systems like field mills, there is no need to install and maintain anything on your site, meaning no investment cost. The METEORAGE Network – the European Lightning Detection Network (ELDN), is fully operational and servicing customers across Europe with optimal reliability. Our subscription-based lightning services are accessible as SaaS (Software as a Service), meaning that you can use them via any device connected to the Internet.
How far back in time does your lightning database go?
Our expertise draws on more than ten years of analysis, observation and data collected in Europe, and more broadly worldwide. METEORAGE has over 37 years’ expertise in France. METEORAGE completed in 1989 the installation of its French lightning detection network.
All the lightning data collected since that date has been saved in the METEORAGE database and can be used to provide services, such as reports and statistics. Throughout the years, the network has been maintained up to date with the latest technology developments to constantly deliver an optimal lightning data quality.
This depth of the database is particularly important for the computation of lightning statistics to provide an accurate assessment of the risk. The IEC 62858 international standard recommends computing them over a period of at least 10 years to take into account long-term cyclical variations of the climate.
Are lightning discharges of low intensity dangerous? Is there a difference between positive (CG+) and negative (CG-) ones?
Any Cloud-to-Ground lightning discharge can cause damages or even kill, even when their intensity is only of a few kA.
Thus, it might be interesting to consider the statistical spread of the intensities to dimension your lightning protections or to compare their LPL (Lightning Protection Level) with the intensity of a damaging stroke.
While the intensity remains the main driver of the induced risk, the polarity also plays a part. Positive CG flashes are rare (~10% of all CG flashes), but more dangerous because they are associated with continuous currents, a phenomenon particularly likely to trigger a fire or an explosion.
How can I reset my Customer area password?
How can I access my invoice after an online purchase?
For more technical explanations on thunderstorms and lightning detection, click here: www.meteorage.com/understanding-thunderstorms-and-lightning
Need more information?
If you can’t find the answer to your question or you need clarification, send us a message.